Große Auswahl an günstigen Büchern
Schnelle Lieferung per Post und DHL

Beobachtung Der Resonanz Zwischen Elektrischer Und Magnetischer Hyperfeinstrukturwechselwirkung. Probleme Der Zeitmessung

Über Beobachtung Der Resonanz Zwischen Elektrischer Und Magnetischer Hyperfeinstrukturwechselwirkung. Probleme Der Zeitmessung

Differential measurements of the angular correlation of the 133-482 ke V cascade in the decay of 181Hf have been performed. The source was prepared by an irradiation of a Hafnium single crystal by thermal neutrons. The analysis of the data proved that the electric field gradient at the position of the nucleus has axial symmetry. The strength of the electric field gradient was derived as: 17 2 Vzz = (5,5 ± 0,3) . 10 Vjcm This calculation is based on the electric quadrupole moment 24 2 Q(I = ~) = (2,5 ± 0,1) ·10- cm By combining the internal field with an external magnetic field the reso­ nance between the electric and magnetic Larmor precession could be observed. The amplitude of the observed spin rotation curve diminishes with increasing time-delay. The reason for this effect is not yet understood. Resume Nous avons effectue des mesures differentielles de la correlation directio­ nelle entre les cascades 133-482 keV du lSlHafnium. La source etait con­ stituee par un monocristal de Hafnium, ayant ete irradie par des neutrons thermiques. L'analyse des mesures montre que le gradient du champ magnetique aupres du noyeau a la symmetrie axiale. Sa valeur est: 17 2 V = (5,5 ± 0,3) .10 Vjcm zz Ce calcul repose sur un moment quadripolaire de 24 2 Q(I = ~) = (2,5 ± 0,1) .10- cm La superposition d'un champ magnetique externe nous a permis d'ob­ server la resonance entre la precession de Larmor electrique et magnetique.

Mehr anzeigen
  • Sprache:
  • Deutsch
  • ISBN:
  • 9783663004387
  • Einband:
  • Taschenbuch
  • Seitenzahl:
  • 62
  • Veröffentlicht:
  • 1. Januar 1969
  • Ausgabe:
  • 1969
  • Abmessungen:
  • 244x170x3 mm.
  • Gewicht:
  • 118 g.
  Versandkostenfrei
  Sofort lieferbar

Beschreibung von Beobachtung Der Resonanz Zwischen Elektrischer Und Magnetischer Hyperfeinstrukturwechselwirkung. Probleme Der Zeitmessung

Differential measurements of the angular correlation of the 133-482 ke V cascade in the decay of 181Hf have been performed. The source was prepared by an irradiation of a Hafnium single crystal by thermal neutrons. The analysis of the data proved that the electric field gradient at the position of the nucleus has axial symmetry. The strength of the electric field gradient was derived as: 17 2 Vzz = (5,5 ± 0,3) . 10 Vjcm This calculation is based on the electric quadrupole moment 24 2 Q(I = ~) = (2,5 ± 0,1) ·10- cm By combining the internal field with an external magnetic field the reso­ nance between the electric and magnetic Larmor precession could be observed. The amplitude of the observed spin rotation curve diminishes with increasing time-delay. The reason for this effect is not yet understood. Resume Nous avons effectue des mesures differentielles de la correlation directio­ nelle entre les cascades 133-482 keV du lSlHafnium. La source etait con­ stituee par un monocristal de Hafnium, ayant ete irradie par des neutrons thermiques. L'analyse des mesures montre que le gradient du champ magnetique aupres du noyeau a la symmetrie axiale. Sa valeur est: 17 2 V = (5,5 ± 0,3) .10 Vjcm zz Ce calcul repose sur un moment quadripolaire de 24 2 Q(I = ~) = (2,5 ± 0,1) .10- cm La superposition d'un champ magnetique externe nous a permis d'ob­ server la resonance entre la precession de Larmor electrique et magnetique.

Kund*innenbewertungen von Beobachtung Der Resonanz Zwischen Elektrischer Und Magnetischer Hyperfeinstrukturwechselwirkung. Probleme Der Zeitmessung



Ähnliche Bücher finden
Das Buch Beobachtung Der Resonanz Zwischen Elektrischer Und Magnetischer Hyperfeinstrukturwechselwirkung. Probleme Der Zeitmessung ist in den folgenden Kategorien erhältlich:

Willkommen bei den Tales Buchfreunden und -freundinnen

Jetzt zum Newsletter anmelden und tolle Angebote und Anregungen für Ihre nächste Lektüre erhalten.