Große Auswahl an günstigen Büchern
Schnelle Lieferung per Post und DHL

Cross Match by Flow Cytometry in renal transplantation

Über Cross Match by Flow Cytometry in renal transplantation

In the course of this work, we were interested in the development and technical validation of XM by CMF, which enabled us to deduce the following conclusions:Concerning the choice of TN, we found that NHP is the best control that can be used. The choice of negative sera in this pool was not based on the criteria of male sex and AB blood group. We plan to take these into account when building a new NHP. For PT, we compared the results provided by a positive serum and a pool of strongly positive sera.In the pure forms of the sera tested, a prozone effect was observed. This is due to the high concentration of anti-HLA Ac, which means that caution should be exercised when using this type of serum as a PT. However, the results were comparable for the poly-specific positive serum diluted at 1/10 and the pool of positive sera diluted at 1/2. We opted for the use of a pool of positive sera for its wider coverage of HLA antigenic specificities.

Mehr anzeigen
  • Sprache:
  • Englisch
  • ISBN:
  • 9786206895824
  • Einband:
  • Taschenbuch
  • Seitenzahl:
  • 52
  • Veröffentlicht:
  • 29. November 2023
  • Abmessungen:
  • 150x4x220 mm.
  • Gewicht:
  • 96 g.
  Versandkostenfrei
  Versandfertig in 1-2 Wochen.

Beschreibung von Cross Match by Flow Cytometry in renal transplantation

In the course of this work, we were interested in the development and technical validation of XM by CMF, which enabled us to deduce the following conclusions:Concerning the choice of TN, we found that NHP is the best control that can be used. The choice of negative sera in this pool was not based on the criteria of male sex and AB blood group. We plan to take these into account when building a new NHP. For PT, we compared the results provided by a positive serum and a pool of strongly positive sera.In the pure forms of the sera tested, a prozone effect was observed. This is due to the high concentration of anti-HLA Ac, which means that caution should be exercised when using this type of serum as a PT. However, the results were comparable for the poly-specific positive serum diluted at 1/10 and the pool of positive sera diluted at 1/2. We opted for the use of a pool of positive sera for its wider coverage of HLA antigenic specificities.

Kund*innenbewertungen von Cross Match by Flow Cytometry in renal transplantation



Ähnliche Bücher finden
Das Buch Cross Match by Flow Cytometry in renal transplantation ist in den folgenden Kategorien erhältlich:

Willkommen bei den Tales Buchfreunden und -freundinnen

Jetzt zum Newsletter anmelden und tolle Angebote und Anregungen für Ihre nächste Lektüre erhalten.