Große Auswahl an günstigen Büchern
Schnelle Lieferung per Post und DHL

Fuse Protection against the Regenerative Circuit Internal Commutation Fault

Über Fuse Protection against the Regenerative Circuit Internal Commutation Fault

Current-limiting fuses are widely used to protect the thyristors in dc drive systems. In the event of the commutation failure when regenerating (inverting), the fuses need to interrupt in loop supplied by the ac and dc voltages acting in series which is the most difficult case for protection by fuse. In this paper, a detailed study of the complete interruption process has been investigated by modeling of arcing process of the fuse. The effect varying the motor time constant, supply impedance, number of fuses used to clear the fault and dc machine rating to the total response for fuses protecting against the regenerative circuit internal commutation fault has been studied. The model of 200A fuse is employed in this study and fuses in series with the semiconductor devices (F1) and fuses in ac line (F2) are both considered.

Mehr anzeigen
  • Sprache:
  • Englisch
  • ISBN:
  • 9798211935136
  • Einband:
  • Taschenbuch
  • Seitenzahl:
  • 24
  • Veröffentlicht:
  • 6. Oktober 2022
  • Abmessungen:
  • 203x2x254 mm.
  • Gewicht:
  • 78 g.
  Versandkostenfrei
  Versandfertig in 1-2 Wochen.
Verlängerte Rückgabefrist bis 31. Januar 2025

Beschreibung von Fuse Protection against the Regenerative Circuit Internal Commutation Fault

Current-limiting fuses are widely used to protect the thyristors in dc drive systems. In the event of the commutation failure when regenerating (inverting), the fuses need to interrupt in loop supplied by the ac and dc voltages acting in series which is the most difficult case for protection by fuse.
In this paper, a detailed study of the complete interruption process has been investigated by modeling of arcing process of the fuse. The effect varying the motor time constant, supply impedance, number of fuses used to clear the fault and dc machine rating to the total response for fuses protecting against the regenerative circuit internal commutation fault has been studied. The model of 200A fuse is employed in this study and fuses in series with the semiconductor devices (F1) and fuses in ac line (F2) are both considered.

Kund*innenbewertungen von Fuse Protection against the Regenerative Circuit Internal Commutation Fault



Ähnliche Bücher finden
Das Buch Fuse Protection against the Regenerative Circuit Internal Commutation Fault ist in den folgenden Kategorien erhältlich:

Willkommen bei den Tales Buchfreunden und -freundinnen

Jetzt zum Newsletter anmelden und tolle Angebote und Anregungen für Ihre nächste Lektüre erhalten.