Große Auswahl an günstigen Büchern
Schnelle Lieferung per Post und DHL

Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics

Highly Stretchable Microflow Sensor for Monitoring of Hemodynamicsvon Woon-Hong Yeo Sie sparen 15% des UVP sparen 15%
Über Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics

Random weakening of an intracranial blood vessel results in abnormal blood flow into an aneurysmal sac. Recent advancements show that a flow-diverter, integrated with a medical stent, enables a highly effective treatment of cerebral aneurysms by guiding blood flow into the normal vessel path. None of such treatment systems, however, offers post-treatment monitoring to assess the progress of sac occlusion. Therefore, physicians rely heavily on either angiography or magnetic resonance imaging, which require a dedicated facility with sophisticated equipment and time-consuming procedures. Here, this work introduces an implantable, stretchable, nanostructured flow-sensor system for quantification of intra-aneurysmal hemodynamics. The open-mesh membrane device is capable of effective implantation in complex neurovascular vessels with extreme stretchability (500% radial stretching) and bendability (180 degrees) for monitoring of the treatment progress. In vitro demonstrations of three types of flow-sensors show quantification of intra-aneurysmal blood flow in a pig aorta and the capability of observation of aneurysm treatment with a great sensitivity (detection limit: 0.032 m/s).

Mehr anzeigen
  • Sprache:
  • Englisch
  • ISBN:
  • 9786139924608
  • Einband:
  • Taschenbuch
  • Seitenzahl:
  • 52
  • Veröffentlicht:
  • 10. Oktober 2018
  • Abmessungen:
  • 150x4x220 mm.
  • Gewicht:
  • 96 g.
  Versandkostenfrei
  Versandfertig in 1-2 Wochen.

Beschreibung von Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics

Random weakening of an intracranial blood vessel results in abnormal blood flow into an aneurysmal sac. Recent advancements show that a flow-diverter, integrated with a medical stent, enables a highly effective treatment of cerebral aneurysms by guiding blood flow into the normal vessel path. None of such treatment systems, however, offers post-treatment monitoring to assess the progress of sac occlusion. Therefore, physicians rely heavily on either angiography or magnetic resonance imaging, which require a dedicated facility with sophisticated equipment and time-consuming procedures. Here, this work introduces an implantable, stretchable, nanostructured flow-sensor system for quantification of intra-aneurysmal hemodynamics. The open-mesh membrane device is capable of effective implantation in complex neurovascular vessels with extreme stretchability (500% radial stretching) and bendability (180 degrees) for monitoring of the treatment progress. In vitro demonstrations of three types of flow-sensors show quantification of intra-aneurysmal blood flow in a pig aorta and the capability of observation of aneurysm treatment with a great sensitivity (detection limit: 0.032 m/s).

Kund*innenbewertungen von Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics



Ähnliche Bücher finden
Das Buch Highly Stretchable Microflow Sensor for Monitoring of Hemodynamics ist in den folgenden Kategorien erhältlich:

Willkommen bei den Tales Buchfreunden und -freundinnen

Jetzt zum Newsletter anmelden und tolle Angebote und Anregungen für Ihre nächste Lektüre erhalten.