Große Auswahl an günstigen Büchern
Schnelle Lieferung per Post und DHL

Performance Analysis of various String Cabling Structures based on Monitoring Values of large PV Plants

Performance Analysis of various String Cabling Structures based on Monitoring Values of large PV Plantsvon Gerhard Mütter Sie sparen 12% des UVP sparen 12%
Über Performance Analysis of various String Cabling Structures based on Monitoring Values of large PV Plants

Large PV plants vary in construction details. The aim of this thesis is to show the different impacts of well-known influence factors especially relevant to large PV parks with more than 10 MWp installed capacity. This thesis is based on the results presented at PVSEC 2014 on the varying relevance of influence factors on performance and will give full particulars on the effects of different string cabling. A comparison is made of two large (>20 MWp) PV plants with very similar technical structures and a distance of less than 10 km distance between the locations and monitoring values were access over a period of more than two years. The main methodology is the comparison of the parks and the correction of the power production caused by local weather differences. Any additional differences and irregularities of other impacts than those caused by cabling are corrected and an estimation of the impact is shown. An optimized park design reveals that design cabling in single row strings leads to ~ 460 000 kWh less losses during one season in the 31.5 MWp park.

Mehr anzeigen
  • Sprache:
  • Englisch
  • ISBN:
  • 9786202208000
  • Einband:
  • Taschenbuch
  • Seitenzahl:
  • 92
  • Veröffentlicht:
  • 14. Februar 2018
  • Abmessungen:
  • 150x7x220 mm.
  • Gewicht:
  • 155 g.
  Versandkostenfrei
  Versandfertig in 1-2 Wochen.

Beschreibung von Performance Analysis of various String Cabling Structures based on Monitoring Values of large PV Plants

Large PV plants vary in construction details. The aim of this thesis is to show the different impacts of well-known influence factors especially relevant to large PV parks with more than 10 MWp installed capacity. This thesis is based on the results presented at PVSEC 2014 on the varying relevance of influence factors on performance and will give full particulars on the effects of different string cabling. A comparison is made of two large (>20 MWp) PV plants with very similar technical structures and a distance of less than 10 km distance between the locations and monitoring values were access over a period of more than two years. The main methodology is the comparison of the parks and the correction of the power production caused by local weather differences. Any additional differences and irregularities of other impacts than those caused by cabling are corrected and an estimation of the impact is shown. An optimized park design reveals that design cabling in single row strings leads to ~ 460 000 kWh less losses during one season in the 31.5 MWp park.

Kund*innenbewertungen von Performance Analysis of various String Cabling Structures based on Monitoring Values of large PV Plants



Ähnliche Bücher finden
Das Buch Performance Analysis of various String Cabling Structures based on Monitoring Values of large PV Plants ist in den folgenden Kategorien erhältlich:

Willkommen bei den Tales Buchfreunden und -freundinnen

Jetzt zum Newsletter anmelden und tolle Angebote und Anregungen für Ihre nächste Lektüre erhalten.