Große Auswahl an günstigen Büchern
Schnelle Lieferung per Post und DHL

Power Factor Improvement of Cascaded Buck- Boost Converter

Power Factor Improvement of Cascaded Buck- Boost Convertervon Amit Kumar Pandey Sie sparen 15% des UVP sparen 15%
Über Power Factor Improvement of Cascaded Buck- Boost Converter

The conventional ac-dc conversion utilizes full wave bridge rectifier, and a capacitor as output filter. The ripple at the output of the capacitor is removed by the voltage regulator (dc-dc converter). Lot of harmonic currents at the load are undesirable because they produce distortion such as electromagnetic field interference (EMI), noise, etc. For distortion less output, line voltage and line current must have same phase. If line voltage and line current are not in same phase, then extra circuits must be adding to the converter to make the circuit in same phase. Line voltage and line current in same phase is called unity power factor, and the technique is called unity power factor correction. For ideal sine wave generator, its higher order harmonic currents do not contribute any power to the load but increase the root mean square (rms) current in the distribution line. As a result, it produces extra losses, which is undesirable. If the boost converter has unity power factor, then maximum active power is transferred to its load. As a result, ideal utility power factor is achieved.

Mehr anzeigen
  • Sprache:
  • Englisch
  • ISBN:
  • 9783330069497
  • Einband:
  • Taschenbuch
  • Seitenzahl:
  • 56
  • Veröffentlicht:
  • 26. Dezember 2018
  • Abmessungen:
  • 150x4x220 mm.
  • Gewicht:
  • 102 g.
  Versandkostenfrei
  Versandfertig in 1-2 Wochen.

Beschreibung von Power Factor Improvement of Cascaded Buck- Boost Converter

The conventional ac-dc conversion utilizes full wave bridge rectifier, and a capacitor as output filter. The ripple at the output of the capacitor is removed by the voltage regulator (dc-dc converter). Lot of harmonic currents at the load are undesirable because they produce distortion such as electromagnetic field interference (EMI), noise, etc. For distortion less output, line voltage and line current must have same phase. If line voltage and line current are not in same phase, then extra circuits must be adding to the converter to make the circuit in same phase. Line voltage and line current in same phase is called unity power factor, and the technique is called unity power factor correction. For ideal sine wave generator, its higher order harmonic currents do not contribute any power to the load but increase the root mean square (rms) current in the distribution line. As a result, it produces extra losses, which is undesirable. If the boost converter has unity power factor, then maximum active power is transferred to its load. As a result, ideal utility power factor is achieved.

Kund*innenbewertungen von Power Factor Improvement of Cascaded Buck- Boost Converter



Ähnliche Bücher finden
Das Buch Power Factor Improvement of Cascaded Buck- Boost Converter ist in den folgenden Kategorien erhältlich:

Willkommen bei den Tales Buchfreunden und -freundinnen

Jetzt zum Newsletter anmelden und tolle Angebote und Anregungen für Ihre nächste Lektüre erhalten.