Große Auswahl an günstigen Büchern
Schnelle Lieferung per Post und DHL

Radiation Exposure and Image Quality in Brain CT Examination

Radiation Exposure and Image Quality in Brain CT Examinationvon Mohamed Abuelheja Sie sparen 16% des UVP sparen 16%
Über Radiation Exposure and Image Quality in Brain CT Examination

The goal of clinical computed tomography (CT) is to produce images of diagnostic quality using the lowest possible radiation exposure. Degradation of image quality, with increased image noise and reduced spatial resolution, is a major limitation for radiation dose reduction in (CT). This can be counteracted with new post-processing image filters and iterative reconstruction (IR) algorithms that improve image quality and allow for reduced radiation doses. Implementation of new methods in clinical routine requires prior validation in phantoms and clinical feasibility studies including comprehensive evaluation of diagnostic image quality. The main objectives of this study were to compromise between radiation dose and image quality in brain (CT) scan at different (mAs) by using(MATLAB) software for evaluation of image quality, a total of 54 human subjects from Abu Salem Trauma Hospital were included in the clinical studies. In conclusion, all evaluated methods improved image quality and showed potential for radiation dose reduction while maintaining diagnostic quality. Careful study design and comprehensive evaluation of image quality including objective and subjective.

Mehr anzeigen
  • Sprache:
  • Englisch
  • ISBN:
  • 9786139973347
  • Einband:
  • Taschenbuch
  • Seitenzahl:
  • 92
  • Veröffentlicht:
  • 19. Dezember 2018
  • Abmessungen:
  • 150x6x220 mm.
  • Gewicht:
  • 155 g.
  Versandkostenfrei
  Versandfertig in 1-2 Wochen.

Beschreibung von Radiation Exposure and Image Quality in Brain CT Examination

The goal of clinical computed tomography (CT) is to produce images of diagnostic quality using the lowest possible radiation exposure. Degradation of image quality, with increased image noise and reduced spatial resolution, is a major limitation for radiation dose reduction in (CT). This can be counteracted with new post-processing image filters and iterative reconstruction (IR) algorithms that improve image quality and allow for reduced radiation doses. Implementation of new methods in clinical routine requires prior validation in phantoms and clinical feasibility studies including comprehensive evaluation of diagnostic image quality. The main objectives of this study were to compromise between radiation dose and image quality in brain (CT) scan at different (mAs) by using(MATLAB) software for evaluation of image quality, a total of 54 human subjects from Abu Salem Trauma Hospital were included in the clinical studies. In conclusion, all evaluated methods improved image quality and showed potential for radiation dose reduction while maintaining diagnostic quality. Careful study design and comprehensive evaluation of image quality including objective and subjective.

Kund*innenbewertungen von Radiation Exposure and Image Quality in Brain CT Examination



Ähnliche Bücher finden
Das Buch Radiation Exposure and Image Quality in Brain CT Examination ist in den folgenden Kategorien erhältlich:

Willkommen bei den Tales Buchfreunden und -freundinnen

Jetzt zum Newsletter anmelden und tolle Angebote und Anregungen für Ihre nächste Lektüre erhalten.