Große Auswahl an günstigen Büchern
Schnelle Lieferung per Post und DHL

Simultaneous Estimation of Cefixime and Linezolid

Über Simultaneous Estimation of Cefixime and Linezolid

Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (250mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 ¿g/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.

Mehr anzeigen
  • Sprache:
  • Englisch
  • ISBN:
  • 9786139454754
  • Einband:
  • Taschenbuch
  • Seitenzahl:
  • 88
  • Veröffentlicht:
  • 21. Februar 2019
  • Abmessungen:
  • 229x152x5 mm.
  • Gewicht:
  • 141 g.
  Versandkostenfrei
  Versandfertig in 1-2 Wochen.

Beschreibung von Simultaneous Estimation of Cefixime and Linezolid

Development and validation of simple, precise, accurate, economical and sensitive HPLC assay method for the estimation of Cefixime and Linezolid in tablet dosage form. A chromatographic separation was achieved with a Hypersil BDS C18 (250mm,4.6mm ,5µm) analytical column. A Mixture of Phosphate Buffer (3.0 pH): methanol (40:60, v/v) was used as the mobile phase, at a flow rate of 1.0 ml/min and detector wavelength at 277 nm. The retention time of Cefixime and linezolid was found to be 3.76 and 6.55 min respectively. Theoretical plates was 6896 and 4626 respectively and Tailing factor was 1.32 and 1.28. The linear ranges was 5-15 for cefixime and 15-45 ¿g/ml for linezolid, and the correlation coefficient was 0.999 for both drugs. The relative standard deviation was found to be less than 2%. A simple, precise, accurate, economical and sensitive HPLC assay method have been developed and validated for the estimation of Cefixime and linezolid in tablet dosage form. All method validation parameters lie within its acceptance crieteria as per ICH Q2(R1) guideline.

Kund*innenbewertungen von Simultaneous Estimation of Cefixime and Linezolid



Ähnliche Bücher finden
Das Buch Simultaneous Estimation of Cefixime and Linezolid ist in den folgenden Kategorien erhältlich:

Willkommen bei den Tales Buchfreunden und -freundinnen

Jetzt zum Newsletter anmelden und tolle Angebote und Anregungen für Ihre nächste Lektüre erhalten.